Vacuum Pump Oil
VACUUM PUMP FLUIDS FOR VACUUM PUMPS
Small Cost offers Big Savings: Oil is inexpensive compared to the high cost of the vacuum pump. Your vacuum pumps require the proper fluid to operate efficiently. Fluids formulated for other purposes contain additives designed to enhance their functions. However, they hinder the performance of the vacuum pump by absorbing moisture, raising vapor pressure and reacting to process gases to form sludge. Use of proper fluids and regular oil changes will give you the lowest obtainable pressure with a minimal amount of repair.
Exhaust: As you evacuate your process chamber condensable vapors are pumped into the vacuum pump. They are then expelled through the exhaust port. If not configured or maintained properly these exhaust vapors condense in the exhaust system and return to the pump where they mix with the oil and clog the filters.
Recommendation: Change exhaust filters regularly. If exhausting outdoors, configure your exhaust line to reduce the amount of condensables that could return to the pump. This can easily be accomplished by installing a vertical leg in the exhaust line which can be drained as needed.
Inlet: During pump down and process, contaminants from the chamber are drawn into the pump through the inlet port. These contaminants along with air mix with the oil causing it to oxidize and form sludge. This will block oil passages and reduce oil flow. Reduced oil flow means slower pumping, longer evacuation time and vacuum pump failure.
Recommendation: Install a filter on the vacuum pump inlet line to stop particulate from reaching the pump. The type of filter media will vary according to your process. Care must be taken in sizing this type of filter so that the pumping speed of your system is not affected.
Starting, Stopping Pumps: The common practice of stopping the pump after every process run is one of the most detrimental things you can do to a vacuum pump. During the process, you pull contaminants, i.e. water, air, etc., into the pump time after time. The pump is then shut off allowing everything to condense in the pump and contaminate the oil.
Recommendation: After each process run, let the pump run with the gas ballast open isolated from your chamber by means of a valve. A hot pump running against a closed valve will clean itself giving you longer pump life and better pumping speed.
Mechanical Pump Fluids
| CVP-100/130 |
Mechanical pumps operating at elevated temperatures |
Resists sludge & varnish formation |
| CVP-153/154 |
General use fluid for food processing |
USDA food plant approved - Hydrocarbon |
| CVP-157/158 |
Sliding rotary vane type vacuum pumps |
USDA food plant approved - Synthetic |
| CVP-159 |
Rapid cycle food processing mechanical pumps |
USDA food plant approved - Synthetic |
| CVP-170 |
Internal cleaning of mechanical vacuum pumps |
Releases contamination from internal parts |
| CVP-177 |
General service, piston & large vane pumps |
Resists water emulsification and oxidation |
| CVP-180 |
General service belt drive rotary vane pumps |
Direct replacement to Welch DuoSeal® |
| CVP-185 |
General use for large mechanical pumps |
Excellent thermal stability & high viscosity |
| CVP-187/188 |
Pumps exposed to high acid contamination |
Effectively neutralizes acid |
| CVP-190 |
General use for laboratory mechanical pumps |
Rapid pumping with low ultimate pressure |
| CVP-195 |
Versatile fluid for all hydrocarbon applications |
Replaces multiple fluids & is OEM approved |
| CVP-198 |
Pumps subject to reactive or corrosive gases |
Molecularly distilled white hydrocarbon |
| CVP-200 |
Vane pumps & blowers backing diffusion pumps |
Direct replacement for HE-200 |
| CVP-405 |
Large belt driven roots type rotary lobe boosters |
Non-foaming offers better lubrication |
| CVP-540/550 |
Cold starts with temperature stability requirements |
Oxidation and chemical resistant - Synthetic |
| CVP-850 |
Hydrocarbon free system for refrigerants |
Compatible with R134A, R12 and R22 |
| Krytox® |
Oxygen service mechanical vacuum pumps |
Reclaimable PFPE oxygen safe no flash/fire |
| Halovac® |
Large pumps in high oxygen application |
Oxygen safe halocarbon fluid, reclaimable |
Diffusion Pump Fluids
| CVP-200 |
Hydrocarbon |
General use high vacuum diffusion pump fluid |
1 x 8 -6 |
| CVP-201 |
Hydrocarbon |
Oxidation resistant high vacuum booster pump fluid |
5 x 10 -6 |
| CVP-300 |
Hydrocarbon |
Formulated for diffusion, booster and ring jet pumps |
3 x 10 -6 |
| CVP-400 |
Hydrocarbon |
Heavy gas loads and high temperature applications |
1 x 10 -5 |
| CVP-702 |
Silicone |
General purpose silicone diffusion pump fluid |
1 x 10 -6 |
| CVP-704 |
Silicone |
Pumps continually cycled to air at operating temperature |
1 x 10 -8 |
| CVP-705 |
Silicone |
Formulated for ultra high vacuum system operations |
1 x 10 -10 |
| Santovac®5 |
Polyphenyl Ether |
Preferred fluid for analytical equipment using vacuum pumps |
4 x 10 -10 |
| CVP-Oil S |
Synthetic Ester |
Standard fluid for leak detectors & mass spectrometers |
5 x 10 -8 |
Specialty Fluids
In our continuing effort to satisfy the vacuum requirements of all our customers, we have specifically engineered a number of specialty fluids.
| CVP-153/154 |
General use fluid for food processing |
USDA food plant approved - Hydrocarbon |
| CVP-157/158 |
Sliding rotary vane type vacuum pumps |
USDA food plant approved - Synthetic |
| CVP-159 |
Rapid cycle food processing mechanical pumps |
USDA food plant approved - Semi-synthetic |
| CVP-850 |
Hydrocarbon free system for refrigerants |
Compatible with R134A, R12 and R22 |
| Krytox® |
Oxygen service mechanical vacuum pumps |
Reclaimable PFPE oxygen safe no flash/fire |
| Halovac® |
Large pumps in high oxygen application |
Oxygen safe halocarbon fluid, reclaimable |
| Santovac®5 |
Polyphenyl Ether |
Preferred fluid for analytical equipment using vacuum pumps |
| CVP-Oil S |
Synthetic Ester |
Standard fluid for leak detectors & mass spectrometers |
| ATK-10 |
Oil Test Kit |
Check condition of oil |
Vacuum Greases
Product # Composition Typical Application Temperature Range
| CVP-9020 |
Silicone |
Vacuum systems as low as 10 -8 |
-40 to 232° |
| Krytox® LVP |
PFPE |
Oxygen service and pressures to 10 -12 |
-20 to 260° |